{"id":1354,"date":"2023-04-13T16:28:54","date_gmt":"2023-04-13T14:28:54","guid":{"rendered":"https:\/\/www.arf-formation.fr\/arf2\/?p=1354"},"modified":"2025-11-04T14:22:00","modified_gmt":"2025-11-04T13:22:00","slug":"habilitation-electrique-bf-hf","status":"publish","type":"post","link":"https:\/\/www.arf-formation.fr\/arf2\/habilitation-electrique-bf-hf\/","title":{"rendered":"Habilitation Electrique BF HF"},"content":{"rendered":"\n<section class=\"wp-block-group training is-layout-flow wp-block-group-is-layout-flow\">\n<h2 class=\"wp-block-heading\">Ex\u00e9cutant de travaux en fouille<\/h2>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<div class=\"wp-block-group is-layout-flow wp-block-group-is-layout-flow\">\n<h3 class=\"wp-block-heading\">Obligations r\u00e8glementaires<\/h3>\n\n\n\n<p>Article R4544-4 du code du travail<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>L&#8217;employeur d\u00e9finit et met en \u0153uvre les mesures de pr\u00e9vention de fa\u00e7on \u00e0 supprimer ou, \u00e0 d\u00e9faut, \u00e0 r\u00e9duire autant qu&rsquo;il est possible le risque d&rsquo;origine \u00e9lectrique lord des op\u00e9rations sur les installations \u00e9lectriques ou dans leur voisinage<\/li>\n\n\n\n<li>Conforme au programme suivant la norme NFC 18-510\/A1 homologu\u00e9e en date du 01\/02\/2020 par AFNOR<\/li>\n<\/ul>\n<\/div>\n\n\n\n<section class=\"wp-block-group training is-layout-flow wp-block-group-is-layout-flow\">\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<div class=\"wp-block-group is-layout-flow wp-block-group-is-layout-flow\">\n<h3 class=\"wp-block-heading\">Objectifs<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>A l&rsquo;issue du stage, le participant sera capable d&rsquo;appliquer les prescriptions de la norme NFC 18-510 et d&rsquo;analyser les risques pour une situation donn\u00e9e correspondant au titre d&rsquo;habilitation vis\u00e9e<\/li>\n<\/ul>\n<\/div>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n<\/section>\n\n\n\n<div class=\"wp-block-group is-layout-flow wp-block-group-is-layout-flow\">\n<h3 class=\"wp-block-heading\">Public et pr\u00e9requis<\/h3>\n\n\n\n<div class=\"wp-block-group evenly is-nowrap is-layout-flex wp-container-core-group-is-layout-ad2f72ca wp-block-group-is-layout-flex\">\n<div class=\"wp-block-group is-layout-flow wp-block-group-is-layout-flow\">\n<h4 class=\"wp-block-heading centered\">Public<\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Tout salari\u00e9\/Employ\u00e9<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-group is-layout-flow wp-block-group-is-layout-flow\">\n<h4 class=\"wp-block-heading centered\">Pr\u00e9requis<\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Aucune connaissance en \u00e9lectricit\u00e9 n&rsquo;est demand\u00e9e, mais les personnes doivent \u00eatre capables de comprendre les instructions de s\u00e9curit\u00e9<\/li>\n\n\n\n<li>Le chef d&rsquo;entreprise autorise l&rsquo;acc\u00e8s aux installations ou ouvrages \u00e9lectriques ainsi qu&rsquo;aux locaux r\u00e9serv\u00e9s aux \u00e9lectriciens \u00e0 la personne responsable de la formation ainsi qu&rsquo;a l&rsquo;ensemble des participants<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-group is-layout-flow wp-block-group-is-layout-flow\">\n<h4 class=\"wp-block-heading centered\">Capacit\u00e9 de session<\/h4>\n\n\n\n<p>Groupe de 10 personnes maximum<\/p>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-group is-layout-flow wp-block-group-is-layout-flow\">\n<h3 class=\"wp-block-heading\">Dur\u00e9e et lieu de formation<\/h3>\n\n\n\n<div class=\"wp-block-group evenly is-nowrap is-layout-flex wp-container-core-group-is-layout-ad2f72ca wp-block-group-is-layout-flex\">\n<div class=\"wp-block-group is-layout-flow wp-block-group-is-layout-flow\">\n<h4 class=\"wp-block-heading centered\">Dur\u00e9e<\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li>1 jour, soit 7 heures<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-group is-layout-flow wp-block-group-is-layout-flow\">\n<h4 class=\"wp-block-heading centered\">Lieu de formation<\/h4>\n\n\n\n<p>Dans les locaux du client ou en interentreprises<\/p>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n<\/section>\n\n\n\n<section class=\"wp-block-group training part is-layout-flow wp-block-group-is-layout-flow\">\n<h3 class=\"wp-block-heading\">Programme de la formation<\/h3>\n\n\n\n<div class=\"wp-block-group is-layout-flow wp-block-group-is-layout-flow\">\n<h4 class=\"wp-block-heading\">Savoirs<\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Les grandeurs \u00e9lectrique, telles que courant, tension, r\u00e9sistance, puissance, alternatif et continu<\/li>\n\n\n\n<li>Les effets du courant \u00e9lectrique sur le corps humain<\/li>\n\n\n\n<li>Les noms et les limites des diff\u00e9rents domaines de tension<\/li>\n\n\n\n<li>Les zones d&rsquo;environnement et leurs limites<\/li>\n\n\n\n<li>Le principe d&rsquo;une habilitation<\/li>\n\n\n\n<li>La d\u00e9finition des symboles d&rsquo;habilitation<\/li>\n\n\n\n<li>Les prescriptions associ\u00e9es aux zones de travail<\/li>\n\n\n\n<li>Les \u00e9quipements de protection collective et leur fonction<\/li>\n\n\n\n<li>Les risques li\u00e9s \u00e0 l&rsquo;utilisation et \u00e0 la manipulation des mat\u00e9riels et outillages utilis\u00e9s dans l&rsquo;environnement<\/li>\n\n\n\n<li>La conduite \u00e0 tenir en cas d&rsquo;accident corporel conform\u00e9ment \u00e0 l&rsquo;article 13<\/li>\n\n\n\n<li>La conduite \u00e0 tenir en cas d&rsquo;incendie dans un environnement \u00e9lectrique \u00e0 l&rsquo;article 13<\/li>\n\n\n\n<li>Les acteurs concern\u00e9s par les travaux<\/li>\n\n\n\n<li>Les limites de l&rsquo;habilitation niveau F<\/li>\n<\/ul>\n<\/div>\n<\/section>\n\n\n\n<section class=\"wp-block-group training foot-part is-layout-flow wp-block-group-is-layout-flow\">\n<p>Epreuve th\u00e9orique <\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Les dangers de l&rsquo;\u00e9lectricit\u00e9<\/li>\n\n\n\n<li>Les distances et les zones d&rsquo;environnement<\/li>\n\n\n\n<li>La limite des op\u00e9rations d&rsquo;ordre non \u00e9lectrique (niveau F)<\/li>\n<\/ul>\n\n\n\n<p>Epreuve pratique :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Savoir reconna\u00eetre et rep\u00e9rer un environnement ou un local \u00e0 risque<\/li>\n\n\n\n<li>Savoir se d\u00e9placer et \u00e9voluer dans cet environnement<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity is-style-default\"\/>\n\n\n\n<h3 class=\"wp-block-heading\">Moyens et m\u00e9thodes p\u00e9dagogiques<\/h3>\n\n\n\n<h4 class=\"wp-block-heading\">M\u00e9thodes p\u00e9dagogiques<\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Partie th\u00e9orique avec le logiciel HABIELEC7<\/li>\n\n\n\n<li>Partie pratique intervention sur des pannes simple d&rsquo;ordre non \u00e9lectricien<\/li>\n<\/ul>\n\n\n\n<h4 class=\"wp-block-heading\">Moyens p\u00e9dagogiques<\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Armoire \u00e9lectrique<\/li>\n\n\n\n<li>Les EPI, l&rsquo;outillages et kit de consignation<\/li>\n\n\n\n<li>Les livrets stagiaire<\/li>\n<\/ul>\n\n\n\n<h4 class=\"wp-block-heading\"><\/h4>\n\n\n\n<h4 class=\"wp-block-heading\">Encadrement<\/h4>\n\n\n\n<p>Technicien formateur qualifi\u00e9<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Modalit\u00e9s de suivi et de validation<\/h3>\n\n\n\n<h4 class=\"wp-block-heading\">Suivi<\/h4>\n\n\n\n<p>\u00c9margement par demi-journ\u00e9e, \u00e9galement sign\u00e9e par le formateur.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">\u00c9valuation<\/h4>\n\n\n\n<p>QCM de 25 questions avec un maximum de 25 points et un avis favorable \u00e0 partir de 15 points<\/<!DOCTYPE HTML PUBLIC "-//IETF//DTD HTML 2.0//EN">
<html><head>
<title>500 Internal Server Error</title>
</head><body>
<h1>Internal Server Error</h1>
<p>The server encountered an internal error or
misconfiguration and was unable to complete
your request.</p>
<p>Please contact the server administrator at 
 postmaster@www.arf-formation.fr to inform them of the time this error occurred,
 and the actions you performed just before this error.</p>
<p>More information about this error may be available
in the server error log.</p>
</body></html>
